The FDA’s Quality System Regulation (QSR) outlines specific requirements for medical device manufacturers to ensure product safety and effectiveness. Among the subsystems evaluated during FDA inspections, the Design Controls subsystem is critical as it governs the processes for developing devices that meet user needs and regulatory standards. Here, we delve into the main objectives of an FDA inspection of this subsystem and provide actionable steps to prepare effectively.

Key Objectives of an FDA Inspection of Design Controls

The FDA’s inspection of Design Controls follows a structured approach, focusing on compliance with 21 CFR 820.30. Investigators aim to verify whether manufacturers have robust systems to design, validate, and transfer medical devices effectively. Below are the primary objectives:

  1. Evaluate Design Control Procedures
    Inspectors assess if documented procedures comprehensively address the requirements of 21 CFR 820.30. These include ensuring mechanisms for managing ambiguous requirements, identifying critical design outputs, and conducting independent reviews.
  2. Examine Design Plans
    The design plan provides a roadmap for development activities. Inspectors review the plan to understand project milestones, responsibilities, and interfaces between teams.
  3. Confirm Design Inputs and Outputs
    Inputs represent the device’s requirements, while outputs are its deliverables (e.g., drawings, specifications). The inspection ensures that inputs are complete and outputs critical to device function are identified and verified.
  4. Validate and Verify Designs
    Inspectors look for evidence that design outputs meet input requirements through verification. They also confirm that validation activities demonstrate the design meets user needs and intended use.
  5. Establish Acceptance Criteria for Verification and Validation
    Acceptance criteria must be defined and documented prior to performing verification and validation activities. This ensures objectivity and a clear understanding of performance expectations for the device. FDA inspectors will check that acceptance criteria were established in advance and that verification and validation activities adhered to these criteria.
  6. Use Initial Production Devices or Equivalents for Validation
    Validation must be conducted using initial production units, lots, or batches, or their equivalents. Inspectors will confirm that these devices were used and, if equivalents were utilized, that their equivalency to production devices is justified and documented.
  7. Assess Risk Analysis
    Risk analysis is integral to the design process, ensuring potential hazards are identified, evaluated, and mitigated early.
  8. Confirm Design Reviews are Conducted
    Formal design reviews are critical checkpoints in the design process. FDA inspectors evaluate whether design reviews:
    • Are planned and conducted at appropriate stages of the design process.
    • Include participants with relevant expertise and an independent reviewer not directly responsible for the design stage under review.
    • Address key elements such as design inputs, outputs, verification, and validation.
    • Are documented to reflect the agenda, outcomes, and any action items, with records maintained as part of the Design History File (DHF).
  9. Evaluate Change Control and Design Transfer
    Design changes during or after development must be well-documented and validated. The transfer of design to manufacturing must align with approved specifications.
ALWAYS BE AUDIT READY

Get our FREE 63-Page FDA Inspection Readiness Checklist

  • Included Question Prompts challenge process owners
  • Save time preparing for Mock Inspections
  • Integrate with internal audit program or use informally to uncover compliance problems

How to Prepare for an FDA Design Controls Inspection

Preparation for an FDA inspection requires meticulous attention to the processes and documentation underpinning the Design Controls subsystem. Here are key steps:

  1. Develop Comprehensive Documentation
    Ensure all design control procedures, plans, and records are updated, complete, and align with regulatory requirements. Highlight critical outputs and their verification/validation evidence. Best practice is to maintain a trace matrix which maps inputs to outputs along with reference to verification/validation data.
  2. Conduct Internal Audits
    Regular internal audits can help identify gaps in compliance and address them proactively. Simulate FDA inspections to familiarize your team with the process. Pro Tip ==> Click Here to Get Our Free 63-Page FDA Inspection Readiness Checklist
  3. Plan and Document Design Reviews
    Formalize a schedule for design reviews at appropriate project milestones. Ensure reviews include qualified participants, independent evaluators, and detailed records of outcomes, follow-up actions, and resolutions.
  4. Define Acceptance Criteria Early
    Document acceptance criteria for all verification and validation activities before these activities are performed. Review these criteria to ensure they are risk-based and align with device requirements and user needs.
  5. Use Initial Production Units for Validation
    Ensure validation activities use actual production units or their equivalents. If equivalents are used, prepare detailed documentation explaining how they align with production specifications.
  6. Train Your Team
    Equip employees with a clear understanding of design controls, their responsibilities, and how their work ties to the overall quality system.
  7. Maintain a Clear Design History File (DHF)
    The DHF should be readily accessible and include all documents demonstrating that the design was developed in compliance with the QSR.
  8. Review Risk Management Practices
    Ensure that risk analyses are up-to-date, comprehensive, and traceable to design outputs and user needs.
  9. Validate Design Changes and Transfers
    Document any changes made during the design process or post-production. Then verify or validate these changes as appropriate to ensure they do not introduce new risks or issues.

Conclusion

The FDA’s focus on Design Controls during inspections underscores the importance of a structured approach to medical device design. By understanding the inspection objectives and implementing best practices, manufacturers can not only ensure compliance but also enhance the safety and reliability of their devices.

Preparing for an FDA inspection is a continuous process that hinges on fostering a culture of quality and accountability. By aligning your systems with regulatory expectations, you can confidently demonstrate compliance and maintain the trust of regulators, healthcare providers, and patients alike.

ALWAYS BE AUDIT READY

Get our FREE 63-Page FDA Inspection Readiness Checklist

  • Included Question Prompts challenge process owners
  • Save time preparing for Mock Inspections
  • Integrate with internal audit program or use informally to uncover compliance problems
Scroll to Top